[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [Megaco] Cancel Service Change (method=Graceful) mechanism




Hi Christian

Thanks for your replies in line...
You would have read my comments to Kevin's response. We would need some changes
to the following if no other alternative is acceptable/ available:
1). Definition of reason "WarmBoot".
2). Definition of method "Restart" which currently states only "service will be
restored on the specified Terminations"

BTW, I am inquisitive - if an MG would typically send a Service Change
(method=Graceful) with finite delay for a termination in Null context. Any
comments?

thanks,
kapil nayar
www.hssworld.com





Christian Groves <Christian.Groves@ericsson.com.au> on 02/04/2003 05:34:44 AM

To:   Kapil Nayar/HSS@HSS
cc:   megaco@ietf.org

Subject:  Re: [Megaco] Cancel Service Change (method=Graceful) mechanism




Hello Kapil,

Please see my comments below.

Christian

knayar@hss.hns.com wrote:
>
> Hi
>
> It seems the protocol doesnot define any procedure for cancelling an earlier
> Service Change (method=Graceful) on a non-root termination.
>
> Taking a practical case:
> MG sends a Service Change (method=Graceful) on a termination with delay= 2
> hours.
> After 1 hour, MG realizes that it doesn't want to put the termination
> out-of-service (after remaining 1 hour) as was earlier intended.
> How to inform the MGC of the new intentions - cancel graceful..?
> Sending Service Change (method =Restart) would mean that termination just came
> InService and doesnot have any active descriptors, whereas this is not the
case.

[CHG] Method = Restart, Reason Warm Boot would work as Kevin mentions.

>
> Solution:
> MG sends Service Change (method = Graceful) delay =2 hours to inform MGC only
> about the intentions.
> MG sends Service Change (method = Forced) when the termination actually goes
> out-of-service after 2 hours.
> This ensures that if Service Change (method = Forced) never came, the
intentions
> of MG never got materialised.
>
> Does any body have an alternative solution? Please suggest.

[CHG] Why do you need to do this? The MGC should have a timer of 2 hours
associated with that termination. So the MGC knows when to subtract the
termination from the context. The MGC should not use this termination for
traffic after it has subtracted it.

>
> thanks,
> kapil nayar
> www.hssworld.com
>
> DISCLAIMER: This message is proprietary to Hughes Software Systems
> Limited (HSS) and is intended solely for the use of the individual
> to whom it is addressed. It may contain  privileged or confidential
> information  and should not be circulated or used for any purpose other
> than for what it is intended. If you have received this message in error,
> please notify the originator immediately. If you are not the intended
> recipient, you are notified that you are strictly prohibited from using,
> copying, altering, or disclosing the contents of this message. HSS accepts
> no responsibility for loss or damage arising from the use of the information
> transmitted by this email including damage from virus.
>
> _______________________________________________
> Megaco mailing list
> Megaco@ietf.org
> https://www1.ietf.org/mailman/listinfo/megaco


_______________________________________________
Megaco mailing list
Megaco@ietf.org
https://www1.ietf.org/mailman/listinfo/megaco




_______________________________________________
Megaco mailing list
Megaco@ietf.org
https://www1.ietf.org/mailman/listinfo/megaco