[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [Megaco] Pulse Metering




Hi!
 
Your definition for pri is taken from the Enable Metering signal. My question was about the Metering Pulse Burst signal. It may well be that the definition of the pri in the Metering Pulse Burst signal is wrong.
 
Regards,
Bruno


De : sun.hongjun at zte.com.cn [mailto:sun.hongjun at zte.com.cn]
Envoyé : vendredi 17 juillet 2009 11:04
À : CHATRAS Bruno RD-CORE-ISS
Objet : 答复: [Megaco] Pulse Metering


Hi
    In H.248.26:
   

Pulse Repetition Interval

ParameterID:        pri (0x0002)

Type:                        Integer

        Possible values:        Any positive integer
        This parameter specifies the interval over which the pulses specified in the pulse count should be issued,

6.5        Procedures
        If the pulse count is greater than 0, then the MG shall determine the appropriate interval between pulses by dividing the pulse repetition interval value by the pulse count. In the event that the interval determined is not integral, then it is the responsibility of the MG to adjust the individual intervals to avoid long-term rounding errors.

     So I think the pri parameter means total interval for all pulses specified in mpb signal.


Michael Sun 孙红军
Network Planning & System Design Department
Product Marketing System
产品市场体系
No.68 Zijinghua Rd,Yuhuatai District, NanJing.P.R.China
Tel:+86-25-52870503
Fax:+86-25-52871000
Email:sun.hongjun at zte.com.cn





<bruno.chatras at orange-ftgroup.com>
发件人:  megaco-bounces at ietf.org

2009-07-17 16:33

收件人
<megaco at ietf.org>
抄送
主题
[Megaco] Pulse Metering





I have a question about the Metering Pulse Burst signal defined in H.248.26 (01/2005). This signal has two parameters: Burst Pulse Count & Pulse Repetion Interval. The Burst Pulse Count parameter specifies the number of metering pulses to be applied as a burst on the line. The description of this parameter says that "The type, duration and pulse repetition interval for the metering pulses comprising the burst are provisioned in the MG".

Considering that the pulse repetition interval is provisioned in the MG, I don't understand the reason why this signal has a "Pulse Repetition Interval" parameter. Furthermore the default value for the "Pulse Repetition Interval" parameter is "1" rather than "provisioned".

Can someone shade some light on this?

Thanks
Bruno

6.3.2.1.1 Burst Pulse Count
Parameter name: Burst Pulse Count
Parameter ID: bpc (0x0001)
Description: This parameter specifies the number of metering pulses to be applied as a burst
on the line. The type, duration and pulse repetition interval for the metering
pulses comprising the burst are provisioned in the MG.
Type: Integer
Optional: Yes
Possible values: 1 or more pulses
Default: 1
6.3.2.1.2 Pulse Repetition Interval

Parameter name: Pulse Repetition Interval
Parameter ID: pri (0x0002)
Description: Interval from the leading edge of a metering pulse to the leading edge of the
next metering pulse.
Type: Integer
Optional: Yes
Possible values: 1 or more milliseconds
Default: 1
_______________________________________________
Megaco mailing list
Megaco at ietf.org
https://www.ietf.org/mailman/listinfo/megaco


--------------------------------------------------------
ZTE Information Security Notice: The information contained in this mail is solely property of the sender's organization. This mail communication is confidential. Recipients named above are obligated to maintain secrecy and are not permitted to disclose the contents of this communication to others.
This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the originator of the message. Any views expressed in this message are those of the individual sender.