Hi Bruno, I guess that it probably means that the MGC may override the MG
provisioned Pulse Repetition Interval. Best regards Silvain From:
megaco-bounces at ietf.org [mailto:megaco-bounces at ietf.org] On Behalf Of bruno.chatras at orange-ftgroup.com I have a
question about the Metering Pulse Burst signal defined in H.248.26 (01/2005).
This signal has two parameters: Burst Pulse Count & Pulse Repetion
Interval. The Burst Pulse Count parameter specifies the number of metering
pulses to be applied as a burst on the line. The description of this parameter
says that "The type, duration and pulse repetition interval for the
metering pulses comprising the burst are provisioned in the MG". Considering
that the pulse repetition interval is provisioned in the MG, I don't understand
the reason why this signal has a "Pulse Repetition Interval"
parameter. Furthermore the default value for the "Pulse Repetition
Interval" parameter is "1" rather than "provisioned". Can someone
shade some light on this? Thanks
6.3.2.1.1 Burst Pulse
Count |