[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: [PWE3] PWE3 question



Andy,

Sure I understand the scaling issue. But ignoring the scalability,
I want to know if it can be done and if so how? 

It seems that you may not be able to use LDP any more, because VC FEC
is meaningless to the interior LSRs. But it seems that you could use
ER-LSPs and therefore do TE. Right? 

Yours,
-Shahram


> -----Original Message-----
> From: Andrew G. Malis [mailto:Andy.Malis@vivacenetworks.com]
> Sent: Tuesday, May 07, 2002 6:12 PM
> To: Shahram Davari
> Cc: 'pwe3@ietf.org'
> Subject: Re: [PWE3] PWE3 question
> 
> 
> Shahram,
> 
> Well, it wouldn't scale very well since every switch along 
> the path is 
> involved in the signaling for each VC, and you can't do traffic 
> engineering, so I would say that's pretty much a non-starter.
> 
> Cheers,
> Andy
> 
> At 5/7/2002 12:02 PM -0700, Shahram Davari wrote:
> >Hi,
> >
> >Can we implement PWE3 with only one label (i.e., only VC label)?
> >
> >-Shahram
> >
> >_______________________________________________
> >pwe3 mailing list
> >pwe3@ietf.org
> >https://www1.ietf.org/mailman/listinfo/pwe3
> 

_______________________________________________
pwe3 mailing list
pwe3@ietf.org
https://www1.ietf.org/mailman/listinfo/pwe3