Open Issues Revision to pktcNcsEndPntConfigCallAgentId description per PC Sig MIB ECx This object contains a string indicating the call agent name (e.g.: ca@example.com). The call agent name, after the character '@', MUST be a fully qualified domain name and MUST have a corresponding pktcMtaDevCmsFqdn entry in the pktcMtaDevCmsTable. The object pktcMtaDevCmsFqdn is defined in the PacketCable MIBMTA Specification. For each particular end-point, the MTA MUST use the current value of this object to communicate with the corresponding CMS. The MTA MUST update this object with the value of the 'Notified Entity' parameter of the NCS messages. Because of the high importance of this object to the ability of the MTA to maintain reliable NCS communication with the CMS, it is highly recommended not to change this object’s value through management station during normal operations. Revision to pktcNcsEndPntConfigCallAgentUdpPort description per PC Sig MIB ECx This object contains the current value of the User Datagram Protocol (UDP) receive port on which the call agent will receive NCS signaling from the endpoint. For each particular end-point, the MTA MUST use the current value of this object to communicate with the corresponding CMS. The MTA MUST update this object with the value of the 'Notified Entity' parameter of the NCS message. If the Notified Entity parameter does not contain a CallAgent port, the MTA MUST update this object with default value of 2727. Because of the high importance of this object to the ability of the MTA to maintain reliable NCS communication with the CMS, it is highly recommended not to change this object’s value through management station during normal operations. |