Network Working Group R. Bergman Request for Comments: 3805 Hitachi Printing Solutions Obsoletes: 1759 H. Lewis Category: Standards Track IBM Corporation I. McDonald High North Inc. June 2004 Printer MIB v2 Status of this Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Copyright Notice Copyright (C) The Internet Society (2004). Abstract This document provides definitions of models and manageable objects for printing environments. The objects included in this MIB apply to physical, as well as logical entities within a printing device. This document obsoletes RFC 1759. Bergman, et al. Standards Track [Page 1] RFC 3805 Printer MIB v2 June 2004 Table of Contents 1. Introduction. . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1. Network Printing Environment. . . . . . . . . . . . . . 4 1.2. Printer Device Overview . . . . . . . . . . . . . . . . 6 1.3. Categories of Printer Information . . . . . . . . . . . 6 1.3.1. Descriptions. . . . . . . . . . . . . . . . . . 6 1.3.2. Status. . . . . . . . . . . . . . . . . . . . . 6 1.3.3. Alerts. . . . . . . . . . . . . . . . . . . . . 6 1.4. The Internet-Standard Management Framework. . . . . . . 7 1.5. Requirement Levels. . . . . . . . . . . . . . . . . . . 7 2. Printer Model . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1. Overview of the Printer Model . . . . . . . . . . . . . 10 2.2. Printer Sub-Units . . . . . . . . . . . . . . . . . . . 10 2.2.1. General Printer . . . . . . . . . . . . . . . . 10 2.2.1.1. International Considerations. . . . . 10 2.2.2. Inputs. . . . . . . . . . . . . . . . . . . . . 11 2.2.3. Media . . . . . . . . . . . . . . . . . . . . . 12 2.2.4. Outputs . . . . . . . . . . . . . . . . . . . . 12 2.2.5. Finishers . . . . . . . . . . . . . . . . . . . 12 2.2.6. Markers . . . . . . . . . . . . . . . . . . . . 13 2.2.7. Media Paths . . . . . . . . . . . . . . . . . . 13 2.2.8. System Controller . . . . . . . . . . . . . . . 14 2.2.9. Interfaces. . . . . . . . . . . . . . . . . . . 14 2.2.10. Print Job Delivery Channels . . . . . . . . . . 14 2.2.11. Interpreters. . . . . . . . . . . . . . . . . . 15 2.2.12. Console . . . . . . . . . . . . . . . . . . . . 15 2.2.13. Alerts. . . . . . . . . . . . . . . . . . . . . 15 2.2.13.1. Status and Alerts . . . . . . . . . . 16 2.2.13.2. Overall Printer Status. . . . . . . . 16 2.2.13.2.1. Host Resources MIB Printer Status. . . . . . 18 2.2.13.2.2. Sub-unit Status . . . . . 20 2.2.13.3. Alert Tables. . . . . . . . . . . . . 21 2.2.13.4. Alert Table Management. . . . . . . . 21 2.3. Read-Write Objects. . . . . . . . . . . . . . . . . . . 23 2.4. Enumerations. . . . . . . . . . . . . . . . . . . . . . 24 2.4.1. Registering Additional Enumerated Values. . . . 25 3. Groups from other MIB Specifications. . . . . . . . . . . . . 25 3.1. System Group. . . . . . . . . . . . . . . . . . . . . . 25 3.2. System Controller . . . . . . . . . . . . . . . . . . . 25 3.3. Interface Group objects . . . . . . . . . . . . . . . . 26 3.3.1. Interface Types . . . . . . . . . . . . . . . . 26 4. Differences from RFC 1759 . . . . . . . . . . . . . . . . . . 26 5. The IANA Printer MIB. . . . . . . . . . . . . . . . . . . . . 29 6. The Printer MIB . . . . . . . . . . . . . . . . . . . . . . . 56 -- Textual conventions for this MIB module. . . . . . . . . . 59 -- The General Printer Group. . . . . . . . . . . . . . . . . 67 Bergman, et al. Standards Track [Page 2] RFC 3805 Printer MIB v2 June 2004 -- The Responsible Party group. . . . . . . . . . . . . . . . 70 -- The Auxiliary Sheet Group. . . . . . . . . . . . . . . . . 73 -- Administrative section (The General V2 Group) . . . . . . 74 -- General alert table section (Alert Table V2 Group). . . . 74 -- The Cover Table. . . . . . . . . . . . . . . . . . . . . . 75 -- The Localization Table . . . . . . . . . . . . . . . . . . 76 -- The System Resources Tables. . . . . . . . . . . . . . . . 78 -- The Input Group. . . . . . . . . . . . . . . . . . . . . . 81 -- The Extended Input Group . . . . . . . . . . . . . . . . . 86 -- The Input Media Group. . . . . . . . . . . . . . . . . . . 87 -- The Input Switching Group. . . . . . . . . . . . . . . . . 89 -- The Output Group . . . . . . . . . . . . . . . . . . . . . 90 -- The Extended Output Group. . . . . . . . . . . . . . . . . 93 -- The Output Dimensions Group. . . . . . . . . . . . . . . . 95 -- The Output Features Group. . . . . . . . . . . . . . . . . 97 -- The Marker Group . . . . . . . . . . . . . . . . . . . . . 98 -- The Marker Supplies Group. . . . . . . . . . . . . . . . . 104 -- The Marker Colorant Group. . . . . . . . . . . . . . . . . 107 -- The Media Path Group . . . . . . . . . . . . . . . . . . . 109 -- The Print Job Delivery Channel Group . . . . . . . . . . . 113 -- The Interpreter Group. . . . . . . . . . . . . . . . . . . 115 -- The Console Group. . . . . . . . . . . . . . . . . . . . . 120 -- The Alerts Group . . . . . . . . . . . . . . . . . . . . . 125 -- Conformance Information. . . . . . . . . . . . . . . . . . 129 7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 147 8. Internationalization Considerations . . . . . . . . . . . . . 147 9. Security Considerations . . . . . . . . . . . . . . . . . . . 148 10. References. . . . . . . . . . . . . . . . . . . . . . . . . . 150 10.1. Normative References. . . . . . . . . . . . . . . . . . 150 10.2. Informative References. . . . . . . . . . . . . . . . . 151 Appendix A - Glossary of Terms. . . . . . . . . . . . . . . . . . 153 Appendix B - Media Size Names . . . . . . . . . . . . . . . . . . 156 Appendix C - Media Names. . . . . . . . . . . . . . . . . . . . . 158 Appendix D - Roles of Users . . . . . . . . . . . . . . . . . . . 162 Appendix E - Overall Printer Status Table . . . . . . . . . . . . 165 Appendix F - Participants . . . . . . . . . . . . . . . . . . . . 166 Significant Contributors. . . . . . . . . . . . . . . . . . . . . 168 Authors' Addresses. . . . . . . . . . . . . . . . . . . . . . . . 170 Full Copyright Statement. . . . . . . . . . . . . . . . . . . . . 171 Bergman, et al. Standards Track [Page 3] RFC 3805 Printer MIB v2 June 2004 1. Introduction 1.1. Network Printing Environment The management of producing a printed document, in any computer environment, is a complex subject. Basically, the task can be divided into two overlapping pieces, the management of printing and the management of the printer. Printing encompasses the entire process of producing a printed document from generation of the file to be printed, selection of a printer, choosing printing properties, routing, queuing, resource management, scheduling, and final printing including notifying the user. Most of the printing process is outside the scope of the model presented here; only the management of the printer is covered. Bergman, et al. Standards Track [Page 4] RFC 3805 Printer MIB v2 June 2004 Figure 1 - One Printer's View of the Network system printer asset user user user manager operator manager O O O O O O /|\ /|\ /|\ /|\ /|\ /|\ / \ / \ / \ / \ / \ / \ | | | | | | +---------+ +-------+ +-------+ +-------+ +-----------+ +-----------+ |configur-| |printer| | asset | |printer| | user | | user | |ator | |manager| |manager| |browser| |application| |application| +---------+ +-------+ +-------+ +-------+ +-----------+ +-----------+ ^ ^ ^ ^ | | |R/W |R/W |R |R +-----------+ +-----------+ | | | | | spooler | | spooler | | | | | +-----------+ +-----------+ | | | | | | | | | | +-----------+ +-----------+ | | | | |supervisor | |supervisor | | | | | +-----------+ +-----------+ | | | | ^ ^ ^ ^ | | | | |R |R/W |R |R/W v v | | | | | | ================================================== | ===== | | print| print| |SNMP data| data| +-----+ +-------+ PCL| PCL| | MIB |<------>| agent | PostScript| PostScript| +-----+ +-------+ NPAP| NPAP| |unspecified etc.| etc.| +=============+ +-----------------+ | | | |--|channel/interface|<--+ | | | +-----------------+ | | PRINTER | | | | +-----------------+ | | |--|channel/interface|<----------------+ +=============+ +-----------------+ Bergman, et al. Standards Track [Page 5] RFC 3805 Printer MIB v2 June 2004 1.2. Printer Device Overview A printer is the physical device that takes media from an input source, produces marks on that media according to some page description or page control language and puts the result in some output destination, possibly with finishing applied. Printers are complex devices that consume supplies, produce waste and may have mechanical problems. In the management of the physical device the description, status and alert information concerning the printer and its various subparts has to be made available to the management application so that it can be reported to the end user, key operators for the replenishment of supplies or the repair or maintenance of the device. The information needed in the management of the physical printer and the management of a printing job overlap highly and many of the tasks in each management area require the same or similar information. 1.3. Categories of Printer Information Information about printers is classified into three basic categories: descriptions, status and alerts. 1.3.1. Descriptions Descriptions convey information about the configuration and capabilities of the printer and its various sub-units. This information is largely static information and does not generally change during the operation of the system but may change as the printer is repaired, reconfigured or upgraded. The descriptions are one part of the visible state of the printer where state means the condition of being of the printer at any point in time. 1.3.2. Status Status is the information regarding the current operating state of the printer and its various sub-units. As an example of the use of status, a management application must be able to determine if the various sub-units are ready to print or are in some state that prevents printing or may prevent printing in the future. 1.3.3. Alerts An Alert is the representation of a reportable event in the printer. An event is a change in the state of the printer. Some of those state changes are of interest to a management application and are therefore reportable. Typically, these are the events that affect the printer's ability to print. Alerts usually occur asynchronously to the operation of the computer system(s) to which the printer is Bergman, et al. Standards Track [Page 6] RFC 3805 Printer MIB v2 June 2004 attached. For convenience below, "alert" will be used for both the event caused by a change in the printer's state and for the representation of that event. Alerts can be classified into two basic categories, critical and non- critical. A critical alert is one that is triggered by entry into a state in which the printer is stopped and printing can not continue until the condition that caused the critical alert is eliminated. "Out of paper", "toner empty" and "output bin full" are examples of critical alerts. Non-critical alerts are triggered by those events that enter a state in which printing is not stopped. Such a non- critical state may, at some future time, lead to a state in which printing may be stopped. Examples of these kinds of non-critical alerts are "input media low", "toner low" and "output bin nearly full". Or, a non-critical alert may simply provide information, such as signaling a configuration changed in the printer. Description, status and alert information about the printer can be thought of as a database describing the printer. The management application for a printer will want to view the printer data base differently depending on how and for what purposes the information in the database is needed. 1.4. The Internet-Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC3410]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580]. 1.5. Requirement Levels The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [RFC2119]. Compliant implementations must follow this specification. Bergman, et al. Standards Track [Page 7] RFC 3805 Printer MIB v2 June 2004 2. Printer Model In order to accomplish the management of the printer, an abstract model of the printer is needed to represent the sub-units from which the printer is composed. A printer can be described as consisting of 13 types of sub-units. It is important to note that the sub-units of a printer do not necessarily relate directly to any physically identifiable mechanism. Sub-units can also be a set of definable logical processes, such as interpreters for page description languages or command processors that set various operating modes of the printer. Figure 2 shows a block diagram of the printer and its basic 13 sub- units. Bergman, et al. Standards Track [Page 8] RFC 3805 Printer MIB v2 June 2004 Figure 2 - Printer Block Diagram Physical Connections | +-----------+ | | +-------------+ | | Interface |-+ | MIB-II | +-------------+ | +-----------+ | | +-------------+ | +-----------+ | Channel |-+ | Operator | | | | Console | +-------------+ +-----------+ | +-----------+ +---------+ | | | | +-----------+ +-------------+ | +-----------+ | | General | | Interpreter |-+ | Alerts |-+ | Printer | | | | | +-----------+ +-------------+ +-----------+ | +-------------------------------+ | System Controller | | HOST-RESOURCES-MIB | +-------------------------------+ +------+ +--------+ +--------+ | | | | | | +-------+ | +-------+ +---------+ | +-------+ +--------+ | | Input |-+ +--------+| | Marker |-+ +--------+| | Output |-+ | |===>| |+<==>| |<==>| |+==>| | +-------+ +--+ +--+ +---------+ +--+ +--+ +--------+ \ | || | || \ \ | || | || \ \ | || | || \ +--------+ | |+-------------------------| || +---------+ | | | +--------------------------+ || | | +----------+ | | Media Path |+ +----------+ | | Media |-+ +--------------------------------+ | Finisher |-+ |(optional)| |(optional)| +----------+ +----------+ Bergman, et al. Standards Track [Page 9] RFC 3805 Printer MIB v2 June 2004 2.1. Overview of the Printer Model The model has three basic parts: (1) the flow of a print file into an interpreter and onto the marker, (2) the flow of media through the marker and (3) the auxiliary sub-units that control and facilitate the two prior flows. The flow of the print data comes through a physical connection on which some form of transport protocol stack is running. The data provided by the transport protocol (interface) appears on a channel, which is the input to an interpreter. The interpreter converts the print data into a form suitable for marking on the media. The media resides in Input sub-units from which the media is selected and then transported via a Media Path first to a Marking sub-unit and then onto an Output sub-unit with (optionally) some finishing operations being performed. The auxiliary sub-units facilitate control of the printer, inquiry/control of the operator panel, reporting of alerts and the adaptation of the printer to various natural languages and characters sets. All the software sub-units run on the System Controller that represents the processor, memory and storage systems of the Printer. Each of the sub-units is discussed in more detail below. All of the sub-units other than the Alerts report only state information, either a description or a status. The Alerts sub-unit reports event information. 2.2. Printer Sub-Units A printer is composed of 13 types of sub-units, called groups. The following sections describe the different types of sub-units. 2.2.1. General Printer The general printer sub-unit is responsible for the overall control and status of the printer. There is exactly one general printer sub- unit in a printer. The General Printer Group in the model represents the general printer sub-unit. In addition to the providing the status of the whole printer and allowing the printer to be reset, this Group provides information on the status of the packaging of the printer, in particular, the covers. The general printer sub-unit is usually implemented on the system controller. 2.2.1.1. International Considerations The localization portion of the general printer sub-unit is responsible for identifying the natural language, country, and character set in which certain character strings are expressed in Bergman, et al. Standards Track [Page 10] RFC 3805 Printer MIB v2 June 2004 this MIB. Character sets are identified in this MIB using the IANACharset textual convention imported from the IANA Character Set MIB [CHARMIB]. There may be one or more localizations supported per printer. The available localizations are specified in the Localization table. Localization SHOULD only be performed on string objects which are named 'xxxDescription' (sub-unit descriptions) or 'prtConsoleDisplayBufferText' (local console text). The agent SHALL return all other character strings in coded character sets in which code positions 0-127 (decimal) are US-ASCII [ASCII]. The agent SHOULD return all other character strings in the UTF-8 [RFC3629] transform of ISO 10646 [ISO10646], to conform with the IETF Policy on Character Sets and Languages [RFC2277]. Control codes (code positions 0-31 and 127 decimal) SHALL NOT be used unless specifically required in the DESCRIPTION of an object. The character set portion of the general printer Localization table is responsible for identifying the possible character sets for the operator console, and network management requests for display objects. There may be one or more character sets per printer. Default coded character sets for interpreter unit and output octets are described in the interpreter sub-unit by prtInterpreterDefaultCharSetIn and prtInterpreterDefaultCharSetOut. These input/output character sets may be overridden by commands in the interpreter language itself. 2.2.2. Inputs Input sub-units are mechanisms that feed media to be marked on into the printer. A printer contains one or more input sub-units. The Input Group in the model represents these. The model does not distinguish fixed input bins from removable trays, except to report when a removable tray has been removed. There are as many input sub-units as there are distinctly selectable input "addresses". For example, if one tray has both a manual and auto feeding option, then this is two input sub-units if these two sources can be (must be) separately selected. However, the above would be considered one input sub-unit if putting a sheet in the manual feed slot overrides feeding from the contents of the tray. In the second case there is no way to separately select or address the manual feed slot. Bergman, et al. Standards Track [Page 11] RFC 3805 Printer MIB v2 June 2004 2.2.3. Media An input sub-unit can hold one or more instances of the media on which marking is to be done. Typically, there is a large set of possible media that can be associated with an input. The Media Group is an extension of the Input Group, which represents media in an input sub-unit. The Media Group only describes the current contents of each input and not the possible content of the input sub-unit. 2.2.4. Outputs Output sub-units are mechanisms that receive media that has been marked on. The Output Group in the model represents the one or more output mechanisms contained by a printer. The model does not distinguish fixed output bins from removable output bins, except to report when a removable bin has been removed. There are as many output sub-units as there are distinctly selectable output "addresses". Output sub-units can be addressed in two different ways: (1) as a set of "mailboxes" which are addressed by a specific mailbox selector such as a bin number or a bin name, or (2) as a set of "slots" into which multiple copies are collated. Sometimes both modes of using the output sub-units can be used on the same printer. All that is important from the viewpoint of the model is that the output units can be separately selected. 2.2.5. Finishers A finisher is a sub-unit that performs some operations on the media other than marking. The Finisher Group in the model represents the finisher sub-units. Some examples of finishing processes are stapling, punching, binding, inserting, or folding. Finishing processes may have supplies associated with the process. Stapling, binding, and punching are examples of processes that have supplies. A printer may have more than one finishing sub-unit and each finishing sub-unit may be associated with one or more output sub- units. Finishers are described in the companion Finisher MIB [RFC3806]. The model does not specify the exact interaction and sequencing between an output device and its associated finisher. It depends on the type of finishing process and the exact implementation of the printer system. This standard allows for the logical association of a finishing process with an output device but does not put any restrictions on the exact sequence or interaction with the associated output device. The output and finisher sub-units may or may not be separate identifiable physical mechanisms depending on the exact Bergman, et al. Standards Track [Page 12] RFC 3805 Printer MIB v2 June 2004 implementation of a printer. In addition, a single output device may be associated with multiple finishing sub-units and a single finishing sub-unit may be associated with multiple output devices. 2.2.6. Markers A marker is the mechanism that produces marks on the print media. The Marker Group in the model represents the marker sub-units and their associated supplies. A printer can contain one or more marking mechanisms. Some examples of multiple marker sub-units are a printer with separate markers for normal and magnetic ink or an image setter that can output to both a proofing device and final film. Each marking device can have its own set of characteristics associated with it, such as marking technology and resolution. In this model the marker sub-unit is viewed as very generalized and encompasses all aspects of a marking process. For example, in a xerographic process, the marking process as well as the fusing process would be included in the generalized concept of the marker. With the generalized concept of a marking process, the concept of multiple marking supplies associated with a single marking sub-unit results. For example, in the xerographic process, there is not only a supply of toner, but there can also be other supplies such as a fuser supply (e.g., fuser oil) that can be consumed and replaced separately. In addition there can be multiple supplies of toner for a single marker device, as in a color process. 2.2.7. Media Paths The media paths encompass the mechanisms in the printer that move the media through the printer and connect all other media related sub- units: inputs, outputs, markers and finishers. A printer contains one or more media paths. The Media Path Group in the model represents these. The Media Path group has some objects that apply to all paths plus a table of the separate media paths. In general, the design of the media paths determines the maximum speed of the printer as well as the maximum media size that the printer can handle. Media paths are complex mechanisms and can contain many different identifiable sub-mechanisms such as media movement devices, media buffers, duplex units and interlocks. Not all of the various sub-mechanisms reside on every media path. For example, one media path may provide printing only on one surface of the media (a simplex path) and another media path may have a sub- mechanism that turns the media over and feeds it a second time through the marker sub-unit (a duplex path). The duplex path may Bergman, et al. Standards Track [Page 13] RFC 3805 Printer MIB v2 June 2004 even have a buffer sub-mechanism that allows multiple copies of the obverse side to be held before the reverse side of all the copies is marked. 2.2.8. System Controller The System Controller is the sub-unit upon which the software components of the Printer run. The Host Resources MIB [RFC2790] represents the System Controller in the model. The Host Resources MIB allows for the specification of the processor(s), memory, disk storage, file system and other underlying sub-mechanisms of the printer. The controller can range from simple single processor systems to multiprocessor systems. In addition, controllers can have a full range of resources such as hard disks. The printer is modeled to have one system controller even though it may have more than one processor and multiple other resources associated with it. 2.2.9. Interfaces An interface is the communications port and associated protocols that are responsible for the transport of data to the printer. A printer has one or more interface sub-units. The interfaces are represented by the Interfaces Group of MIB-II [RFC1213], [RFC2863]. Some examples of interfaces are serial ports (with little or no protocol) and Ethernet ports on which one might run Internet IP, Novell IPX, etc. 2.2.10. Print Job Delivery Channels The print job delivery channel sub-units identify the independent sources of print data (here print data is the information that is used to construct printed pages and may have both data and control aspects). A printer may have one or more channels. The channel sub- units are represented by the Print Job Delivery Channel Group in the Model. The electronic path typically identifies each channel and service protocol used to deliver print data to the printer. A channel sub-unit may be independently enabled (allowing print data to flow) or disabled (stopping the flow of print data). It has a current Control Language that can be used to specify which interpreter is to be used for the print data and to query and change environment variables used by the interpreters (and SNMP). There is also a default interpreter that is to be used if an interpreter is not explicitly specified using the Control Language. Print Job Delivery Channel sub-units can, and usually are, based on an underlying interface. Bergman, et al. Standards Track [Page 14] RFC 3805 Printer MIB v2 June 2004 2.2.11. Interpreters The interpreter sub-units are responsible for the conversion of a description of intended print instances into images that are to be marked on the media. A printer may have one or more interpreters. The Interpreter Group in the Model represents the interpreter sub- units. Each interpreter is generally implemented with software running on the System Controller sub-unit. The Interpreter Table has one entry per interpreter where the interpreters include both Page Description Language (PDL) Interpreters and Control Language Interpreters. 2.2.12. Console Many printers have a console on the printer, the operator console that is used to display and modify the state of the printer. The console can be as simple as a few indicators and switches or as complicated as full screen displays and keyboards. There can be at most one such console. The Console Group in the model represents this console sub-unit. Although most of the information displayed there is also available in the state of the printer as represented by the various Groups, it is useful to be able to query and modify the operator console remotely. For example, a management application might like to display to its user the current message on the operator console of the remote printer or the management application user might like to modify the current message on the operators console of the remote printer. As another example, one might have a remote application that puts up a pseudo console on a workstation screen. Since the rules by which the printer state is mapped onto the console and vice versa are not standardized, it is not possible to reproduce the console state or the action of console buttons and menus. Therefore, the Console Group provides access to the console. The operator console is usually implemented on the system controller with additional hardware for input and display. 2.2.13. Alerts The alert sub-unit is responsible for detecting reportable events, making an entry in the alert table and, if and only if the event is a critical event, initiating a trap. The exception to this rule is when the "alertRemovalofBinaryChangeEntry" trap is generated. The alert sub-unit is represented by the Alerts Group and, in particular, the Alert Table. This table contains information on the severity, sub- unit, and detailed location within the sub-unit, alert code and description of each alert that is currently active within the printer. Each reportable event causes an entry to be made in the Alert Table. Bergman, et al. Standards Track [Page 15] RFC 3805 Printer MIB v2 June 2004 2.2.13.1. Status and Alerts Summary information about the state of the printer is reported at three separate levels: (1) The status of the printer as a whole is reported in the Host Resources MIB, (2) The status of various sub- units is reported in the principle table of the Group that represents the sub-unit, and (3) Alert codes are reported in the Alert Table. 2.2.13.2. Overall Printer Status Of the many states a printer can be in, certain states are more "interesting" because of the distinct actions they are likely to provoke in the administrator. These states may be applied to the printer as a whole, or to a particular sub-unit of the printer. These named states are: Non Critical Alert Active - For the printer this means that one or more sub-units have a non-critical alert active. For a sub-unit, this means that the sub-unit has a non-critical alert active. Critical Alert Active - For the printer this means that one or more sub-units have a critical alert active. For a sub-unit, this means that the sub-unit has a critical alert active. Unavailable - The printer or sub-unit is unavailable for use (this is the same as "broken" or "down" in other terminology). A trained service person is typically necessary to make it available. Moving on-line or off-line - The printer is either off-line, in the process of moving off-line or moving back on-line. For example, on printers with motorized hoppers, reloading paper involves a transition to off-line to open the paper bin, filling the hopper and, finally, a transition back to on-line as the paper bin is repositioned for printing. Standby - The printer or sub-unit is not immediately available but can accept new instructions. Available - The printer or subunit is functioning normally. Idle - The printer or subunit is immediately available. Active - The printer or subunit is performing its primary function. Busy - The printer or subunit is performing a function (not necessarily its primary function) and is not immediately available for its primary function. Bergman, et al. Standards Track [Page 16] RFC 3805 Printer MIB v2 June 2004 The Host Resources MIB [RFC2790] provides three status objects that can be used to describe the status of a printer: (1) hrDeviceStatus in the entry in the hrDeviceTable; (2) hrPrinterStatus in the hrPrinterTable; and (3) hrPrinterDetectedErrorState in the hrPrinterTable. These objects describe many of the states that a printer can be in. The following table shows how the values of the three printer-related objects in the Host Resources MIB relate to the states named above: Printer hrDeviceStatus hrPrinterStatus hrPrinterDetected- Status ErrorState Idle running(2) idle(3) none set Busy/ running(2) printing(4) Active Non Critical warning(3) idle(3) or could be: lowPaper, Alert Active printing(4) lowToner, or serviceRequested Critical down(5) other(1) could be: jammed, Alert Active noPaper, noToner, coverOpen, or serviceRequested Unavailable down(5) other(1) Moving off- warning(3) idle(3) or offline line printing(4) Off-line down(5) other(1) offline Moving down(5) warmup(5) on-line Standby running(2) other(1) These named states are only a subset of the possible states - they are not an exhaustive list of the possible states. Nevertheless, several things should be noted. When using these states, it is not possible to detect when both critical and non-critical alerts are pending - if both are pending, the Critical Alert Active state will prevail. In addition, a printer in the Standby state will be represented in the Host Resources MIB with a device status of running(2) and a printer status of other(1), a set of states that don't uniquely distinguish this important printer state. Bergman, et al. Standards Track [Page 17] RFC 3805 Printer MIB v2 June 2004 Detailed status per sub-unit is reported in the sub-unit status fields. 2.2.13.2.1. Host Resources MIB Printer Status For completeness, the definitions of the Printer Status objects of the Host Resources MIB [RFC2790] are given below: hrDeviceStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), running(2), warning(3), testing(4), down(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. running(2) indicates that the device is up and running and that no unusual error conditions are known. The warning(3) state indicates that agent has been informed of an unusual error condition by the operational software (e.g., a disk device driver) but that the device is still 'operational'. An example would be high number of soft errors on a disk. A value of testing(4), indicates that the device is not available for use because it is in the testing state. The state of down(5) is used only when the agent has been informed that the device is not available for any use." ::= { hrDeviceEntry 5 } hrPrinterStatus OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), idle(3), printing(4), warmup(5) } ACCESS read-only STATUS mandatory DESCRIPTION Bergman, et al. Standards Track [Page 18] RFC 3805 Printer MIB v2 June 2004 "The current status of this printer device. When in the idle(3), printing(4), or warmup(5) state, the corresponding hrDeviceStatus should be running(2) or warning(3). When in the unknown(2) state, the corresponding hrDeviceStatus should be unknown(1)." ::= { hrPrinterEntry 1 } hrPrinterDetectedErrorState OBJECT-TYPE SYNTAX OCTET STRING (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This object represents any error conditions detected by the printer. The error conditions are encoded as an OCTET STRING with the following definitions: Condition Bit # lowPaper 0 noPaper 1 lowToner 2 noToner 3 doorOpen 4 jammed 5 offline 6 serviceRequested 7 inputTrayMissing 8 outputTrayMissing 9 markerSupplyMissing 10 outputNearFull 11 outputFull 12 inputTrayEmpty 13 overduePreventMaint 14 Bit # 15 is not assigned. If multiple conditions are currently detected and the hrDeviceStatus would not otherwise be unknown(1) or testing(4), the hrDeviceStatus shall correspond to the worst state of those indicated, where down(5) is worse than warning(3), which is worse than running(2). Bits are numbered starting with the most significant bit of the first byte being bit 0, the least significant bit of the first byte being bit 7, the most significant bit of the second byte being bit 8, and so on. A one bit encodes that the condition was detected, while a zero bit encodes that Bergman, et al. Standards Track [Page 19] RFC 3805 Printer MIB v2 June 2004 the condition was not detected. This object is useful for alerting an operator to specific warning or error conditions that may occur, especially those requiring human intervention." ::= { hrPrinterEntry 2 } 2.2.13.2.2. Sub-unit Status Sub-unit status is reported in the entries of the principle table in the Group that represents the sub-unit. For sub-units that report a status, there is a status column in the table and the value of this column is always an integer formed in the following way. The PrtSubUnitStatusTC is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line State is On-Line 0 State is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64 Bergman, et al. Standards Track [Page 20] RFC 3805 Printer MIB v2 June 2004 For example, an input (tray) that jammed on the next to the last page may show a status of 27 (unavailable because broken (3) + a critical state (16), jammed, and a noncritical state (8), low paper). 2.2.13.3. Alert Tables The Alert Group consists of a single table in which all active alerts are represented. This section provides an overview of the table and a description of how it is managed. The basic content of the alert table is the severity (critical or non-critical) of the alert, the Group and entry where a state change caused the alert, additional information about the alert (a more detailed location, an alert code, and a description), and an indication of the level of training needed to service the alert. The Alert Table contains some information that is redundant, for example that an event has occurred, and some information that is only represented in the Alert Table, for example the additional information. A single table was used because a single entry in a group could cause more than one alert, for example paper jams in more than one place in a media path. Associating the additional information with the entry in the affected group would only allow one report where associating the additional information with the alert makes multiple reports possible. Every time an alert occurs in the printer, the printer makes one or more entries into the Alert Table. The printer determines if an event is to be classified as critical or non-critical. If the severity of the Alert is "critical", the printer sends a trap or event notification to the host indicating that the table has changed. Whether or not a trap is sent, the management application is expected to poll the printer on a regular basis and to read and parse the table to determine what conditions have changed, in order to provide reliable information to the management application user. 2.2.13.4. Alert Table Management The alert tables are sparsely populated tables. This means the tables will only contain entries of the alerts that are currently active and the number of rows, or entries in the table will be dynamic. More than one event can be added or removed from the event tables at a time depending on the implementation of the printer. There are basically two kinds of events that produce alerts: binary change events and unary change events. Binary change events come in pairs: the leading edge event and the trailing edge event. The leading edge event enters a state from which there is only one exit; for example, going from running to stopped with a paper jam. The only exit from this state is fixing the paper jam and it is clear Bergman, et al. Standards Track [Page 21] RFC 3805 Printer MIB v2 June 2004 when that is accomplished. The trailing edge event exits the state that was entered by the leading edge event. In the example above, fixing the paper jam is the trailing edge event. It is relatively straightforward to manage binary change events in the Alert Table. Only the leading edge event makes an entry in the alert table. This entry persists in the Alert Table until the trailing edge event occurs at which point this event is signaled by the removal of the leading edge event entry in the Alert Table. That is, a trailing edge event does not create an entry; it removes the corresponding leading edge event. Removing the leading edge entry may cause the unary change event "alertRemovalofBinaryChangeEntry" to be added to the table. With binary change events it is possible to compute the maximum number that can occur at the same time and construct an Alert Table that would hold that many events. There would be no possibility of table overflow and no information about outstanding events would be lost. Unfortunately, there are some events that are not binary changes. This other category of event, the unary change event, is illustrated by the configuration change event. With this kind of event the state of the machine has changed, but to a state which is (often) just as valid as the state that was left and from which no return is necessary. For example, an operator may change the paper that is in the primary input source from letter to legal. At some time in the future the paper may be changed back to letter, but it might be changed to executive instead. This is where the problem occurs. It is not obvious how long to keep unary change event entries in the Alert Table. If they were never removed, the Alert Table would continue to grow indefinitely. The agent needs to have an algorithm implemented for the management of the alert table, especially in the face of combinations of binary and unary alerts that would overflow the storage capacity of the table. When the table is full and new alerts need to be added, an old alert to be deleted should be chosen using the following rules: 1. Find a non-critical unary alert and delete it. If there are multiple non-critical unary alerts, it is suggested that the oldest one is chosen. If there are no non-critical unary alerts, then, 2. Find a non-critical binary alert and delete it. If there are multiple non-critical binary alerts, it is suggested that the oldest one is chosen. If there are no non-critical binary alerts, then, Bergman, et al. Standards Track [Page 22] RFC 3805 Printer MIB v2 June 2004 3. Find a critical (binary) alert and delete it. If there are multiple critical alerts, it is suggested that the oldest one be chosen. Agent implementers are encouraged to provide at least enough storage space for the maximum number of critical alerts that could occur simultaneously. Note that all critical alerts are binary. In the event that a critical binary alert has been deleted out of the alert table; when space allows and the alert condition still exists, the alert should be re-added to the alert table even if there was no subsequent transition into the associated state. It is recommended that this be done for non-critical binary alerts as well. Note that the new alert entry will not have the same index as the original entry that was moved out of the table. Note that because the Alert Index is a monotonically increasing integer there will be gaps in the values in the table when an alert is deleted. The management application may want to re-acquire the Printer state and check for state changes that it did not observe in the Alert Table if such gaps are detected. 2.3. Read-Write Objects Some objects in the printer MIB reflect the existence or amount of a given resource within the printer. Some examples of such resources are the size and number of sheets in a paper tray or the existence of certain output options. Some printers have automatic sensors for these resources. Most printers lack sensors for every property of every resource. The management application is allowed to write into objects that hold descriptive or existence values for printers that cannot sense these values. The ability to change the value of a read- write object may depend on the implementation of the agent. Many objects in the MIB are given read-write access, but a printer implementation might only permit a management application to change the value if the printer can not sense the value itself. Note that even though some objects explicitly state the behavior of conditional ability to change values, any read-write object may act this way. Generally, an object is given read-write access in the Printer MIB specification if: 1. The object involves installation of a resource that some printers cannot themselves detect. Therefore, external means are needed to inform the printer of the installation. (Here external means include using the operator console, or remote management application) and Bergman, et al. Standards Track [Page 23] RFC 3805 Printer MIB v2 June 2004 2. The printer will behave differently if the installation of the resource is reported than the printer would if the installation were not reported; that is, the object is not to be used as a place to put information not used by the printer, i.e., not a "sticky-note". Another way of saying this is that the printer believes that information given it and acts as if the information were true. For example, on a printer that cannot sense the size, if one paper size is loaded, but another size is set into the paper size object, then the printer will use the size that was set as its current paper size in its imaging and paper handling. 3. The printer may get hints that it may not know about the existence or properties of certain resources. For example, a paper tray may be removed and re-inserted. When this removal and insertion happens, the printer may either assume that a property, such as the size of paper in the tray, has not changed or the printer may change the value of the associated object to "unknown", as might be done for the amount of paper in the tray. As long as the printer acts according to the value in the object either strategy is acceptable. 4. It is an implementation-specific matter as to whether or not MIB object values are persistent across power cycles or cold starts. It is particularly important that the values of the prtMarkerLifeCount object persist throughout the lifetime of the printer. Therefore, if the value of any MIB object persists across power cycles, then the prtMarkerLifeCount object must also persist. 2.4. Enumerations Enumerations (enums) are sets of symbolic values defined for use with one or more objects. Commonly used enumeration sets are assigned a symbolic data type name (textual convention), rather than being specified in the SYNTAX clause of each individual object definition. Textual conventions defined in the Printer MIB or the companion IANA Printer MIB are extensible by RFC publication or by Designated Expert Review (see the 'IANA Considerations' section of this Printer MIB and the DESCRIPTION clause in MODULE-IDENTITY of IANA Printer MIB). All of these textual conventions are: a) used more than once in the Printer MIB itself; or b) imported and used in the companion Finisher MIB; or c) imported and used in any other, including vendor private, MIB modules. Bergman, et al. Standards Track [Page 24] RFC 3805 Printer MIB v2 June 2004 The Printer MIB has also defined the following special values for use with objects of the syntax "Integer32" to define conditions that are outside of the normal numeric range: other(-1), unknown(-2), and partial(-3). The 'partial' value means that there is some supply remaining (but the amount is indeterminate) or there is some capacity remaining (but the amount is indeterminate). The Integer32 range field indicates in which objects these special values are valid. 2.4.1. Registering Additional Enumerated Values The Printer MIB and the companion IANA Printer MIB each defines one category of textual convention, according to the process employed to control the addition of new enumerations: Type 1 - All of the legal values are defined in the Printer MIB. Additional enumerated values require the publication of a new Printer MIB. Type 2 - All of the legal values are registered in the IANA Printer MIB. Additional enumerated values require a Designated Expert Review defined in "Guidelines for Writing an IANA Considerations Section in RFCs" [RFC2434]. The Designated Expert will be selected by the IETF Area Director(s) of the Applications Area. 3. Groups from other MIB Specifications This section identifies the groups from other MIBs that shall be supported to supplement and complete a printer MIB implementation. The section also describes some of the less obvious characteristics of the Printer MIB structure that are related to the inclusion of these other MIB groups. 3.1. System Group All objects in the system group of MIB-II [RFC1213] shall be implemented; however, as described in paragraph 2.4, implementers should carefully consider what constitutes the "system". 3.2. System Controller The storage and device groups of the Host Resources MIB [RFC2790] shall be implemented to support the printer(s) system controller, and any supporting devices. If deemed appropriate by the implementer, other groups of the Host Resources MIB (System, Running Software, Running Software Performance, and Installed Software) may be implemented. Because of the structure of the Host Resources MIB, the devices constituting the system controller are at the same level as the printer. Bergman, et al. Standards Track [Page 25] RFC 3805 Printer MIB v2 June 2004 3.3. Interface Group objects All objects in the Interfaces Group of MIB-II [RFC1213] shall be implemented for all print information interfaces to the printer, including non-network interfaces. 3.3.1. Interface Types The interfaces group of RFC 1213 [RFC1213] contains only a partial list of interface types that can be specified in the "ifType" object. For a complete list of interface types, refer to the IANA registry at "ftp://ftp.isi.edu/mib/iana.mib/ianaiftype.mib" 4. Differences from RFC 1759 This document supersedes and replaces RFC 1759. However, a compliant implementation of RFC 1759 is also compliant with this document. The following changes to RFC 1759 are included: (See the printmib REVISION/DESCRIPTION clause for additional details of changes.) - Minor editorial corrections and changes. Updated the cover page and added the "SNMP Management Framework" boilerplate to section 1. - Updated figure 2 to use MIB names instead of RFC numbers. - Updated Coded Character Set description and IANA registration process. - Change hrPrinterDetectedErrorState "coverOpen" (bit 4) to "doorOpen" per RFC 2790. - Added second octet of hrPrinterDetectedErrorState as partially described and assigned in the updated Host Resources MIB (RFC 2790). - Remove fixed association of hrDeviceStatus (warning/down) from hrPrinterDetetctedErrorState per RFC 2790. - Instead of showing bit 15 as "not assigned" in the quote from RFC 2790 in the hrPrinterDetectedErrorState object, removed that from the tabular form and added it as a sentence, because the RFC doesn't show bit 15 in the tabular form. - Clarified the international considerations. Bergman, et al. Standards Track [Page 26] RFC 3805 Printer MIB v2 June 2004 - Added prtChannelInformation to the Channel Group textual- conventions on a per channel basis to clarify the channel description and enhance interoperability. - Deprecated some obsolete channel types. - Extended the Alert Table and PrtMarkerSuppliesSupplyUnit textual conventions to include values from the Finisher MIB. - Clarified alerts based on unary vs. binary change events. - Added (optional) unary change event alertRemovalOfBinaryChangeEntry(1801). - Establish a convention for contact information for prtGeneralCurrentOperator and prtGeneralServicePerson. - Added prtAuxiliarySheetStartupPage PresentOnOff - Added prtAuxiliarySheetBannerPage PresentOnOff - Added prtGeneralPrinterName OCTET STRING - Added prtGeneralSerialNumber OCTET STRING - Added prtInputNextIndex Integer32 - Added the Input Switching Group - Added prtAlertCriticalEvents Counter32 - Added prtAlertAllEvents Counter32 - Updated PrtAlertCode enums including generic alert codes. - Created five OBJECT-GROUPs (prtAuxilliarySheetGroup, prtInputSwitchingGroup, prtGeneralV2Group, prtAlertTableV2Group, prtChannelV2Group). Added the nine new objects to them (prtAuxiliarySheetStartupPage, prtAuxiliarySheetBannerPage, prtGeneralPrinterName, prtGeneralSerialNumber, prtAlertCriticalEvents, prtAlertAllEvents, prtInputMediaLoadTimeout, prtInputNextIndex, prtChannelInformation). Created one new NOTIFICATION-GROUP (prtAlertTrapGroup) to contain printerV2Alert. Included the new OBJECT-GROUPs and the NOTIFICATION_GROUP in prtMIBCompliance, all in GROUP (not MANDATORY-GROUP) clauses. The nine new objects are optional, i.e., this document is backward compatible with RFC 1759. Bergman, et al. Standards Track [Page 27] RFC 3805 Printer MIB v2 June 2004 - prtAlertTime is strongly recommended. - Deprecated the use of alert codes doorOpen(501) and doorClosed(502), in favor of coverOpened(3) and coverClosed(4). - Added the PrtConsoleDisableTC and PrtMarkerAddressabilityUnitTC textual conventions, and changed the PrtConsoleDisable and PrtMarkerAddressabilityUnit objects' syntax to use those TCs, and changed the PrtGeneralEntry and PrtMarkerColorantEntry SEQUENCEs to reflect the new syntax. - Added textual conventions "PrtLocalizedDescriptionStringTC" and "PrtConsoleDescriptionStringTC" and updated several objects to use them. - Changed most enumerations to textual conventions and therefore changed the SYNTAX of many objects from RFC 1759 to specify the appropriate textual conventions. (28 TCs were added.) - Changed the TC names "MediaUnit" to "PrtMediaUnitTC", "CapacityUnit" to "PrtCapacityUnitTC", and "SubUnitStatus" to "PrtSubUnitStatusTC" - All objects with a MAX-ACCESS of read-write now have a MIN-ACCESS of read-only. - Added 'IANA Considerations' and 'Internationalization Considerations' as top level sections, per IETF guidelines. - Updated Security and Copyright sections. - Updated references and split into Normative and Informative groups. - Added Appendix E - Overall Printer Status Table. - Updated participant and contact information. - Removed CodedCharSet Textual Convention, replaced with an import of the IANACharset. - Removed all comment statements that indicated objects or groups are mandatory or optional. Avoids any potential conflicts with the conformance section. Bergman, et al. Standards Track [Page 28] RFC 3805 Printer MIB v2 June 2004 - Added text to empty description clauses. (prtStorageRefTable, prtDeviceRefTable, prtMarkerTable, prtMediaPathTable, prtChannelTable, prtInterpreterTable, prtConsoleLightTable, and prtAlertTable) - Added "DEFVAL { unknown }" to prtInterpreterDefaultCharSetIn and prtInterpreterDefaultCharSetOut. - Changed "...values are expected to remain stable..." to "...values SHOULD remain stable..." in the description clauses for the index object in all tables. - Added ranges to all objects with a syntax of Integer32. - Revised the description clause for prtAlertGroupIndex. - Added additional text to the description clause for prtMediaPathEntry, prtChannelEntry, prtInterpreterEntry, and printerV2Alert. - Added text to section 2.4 to explain the usage of textual conventions in this MIB and others. Also added a note defining the common usage of the enumerations 'other(-1)' and 'unknown(-2)' - Changed range of prtStorageRefSeqNumber, prtDeviceRefSeqNumber, and prtConsoleLightIndex from (0..65535) to (1..65535) since index values cannot be zero. (Typo in RFC 1759) - The PWG Standard for Standardized Media Names is now recommended for the objects prtInputMediaName, prtInputMediaColor, and prtInputMediaType. - Added chSMTP(45) to prtChannelTypeTC. 5. The IANA Printer MIB IANA-PRINTER-MIB DEFINITIONS ::= BEGIN -- http://www.iana.org/assignments/ianaprinter-mib IMPORTS MODULE-IDENTITY, mib-2 FROM SNMPv2-SMI -- [RFC2578] TEXTUAL-CONVENTION FROM SNMPv2-TC; -- [RFC2579] ianaPrinterMIB MODULE-IDENTITY LAST-UPDATED "200406020000Z" -- June 2, 2004 Bergman, et al. Standards Track [Page 29] RFC 3805 Printer MIB v2 June 2004 ORGANIZATION "IANA" CONTACT-INFO "Internet Assigned Numbers Authority Postal: ICANN 4676 Admiralty Way, Suite 330 Marina del Rey, CA 90292 Tel: +1 310 823 9358 E-Mail: iana@iana.org" DESCRIPTION "This MIB module defines a set of printing-related TEXTUAL-CONVENTIONs for use in Printer MIB (RFC 3805), Finisher MIB (RFC 3806), and other MIBs which need to specify printing mechanism details. Any additions or changes to the contents of this MIB module require either publication of an RFC, or Designated Expert Review as defined in RFC 2434, Guidelines for Writing an IANA Considerations Section in RFCs. The Designated Expert will be selected by the IESG Area Director(s) of the Applications Area. Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3805. For full legal notices see the RFC itself or see: http://www.ietf.org/copyrights/ianamib.html" REVISION "200406020000Z" -- June 2, 2004 DESCRIPTION "Original version, published in coordination with Printer MIB (RFC 3805)." ::= { mib-2 109 } -- -- Generic TEXTUAL-CONVENTIONs -- PrtCoverStatusTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtCoverStatus in RFC 1759. STATUS current DESCRIPTION "Values for encoding the state of a particular cover or access panel on the printer case or enclosure." SYNTAX INTEGER { other(1), coverOpen(3), coverClosed(4), interlockOpen(5), interlockClosed(6) Bergman, et al. Standards Track [Page 30] RFC 3805 Printer MIB v2 June 2004 } -- -- General Group TEXTUAL-CONVENTIONs -- PrtGeneralResetTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtGeneralReset in RFC 1759. STATUS current DESCRIPTION "Values for reading and writing the prtGeneralReset object. If a device does not have NVRAM, the device shall none the less respond to a SET with the value resetToNVRAM(5) with a sort of warm reset that resets the device to implementation- defined state that is preferably under control of the system administrator by some means outside the scope of the Printer MIB specification." SYNTAX INTEGER { notResetting(3), powerCycleReset(4), -- Cold Start resetToNVRAM(5), -- Warm Start resetToFactoryDefaults(6) -- Reset contents of -- NVRAM to factory -- defaults } -- -- Channel Group TEXTUAL-CONVENTIONs -- PrtChannelTypeTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtChannelType in RFC 1759. STATUS current DESCRIPTION "This enumeration indicates the type of channel that is receiving jobs." SYNTAX INTEGER { other(1), chSerialPort(3), chParallelPort(4), chIEEE1284Port(5), chSCSIPort(6), chAppleTalkPAP(7), -- AppleTalk Printer -- Access Protocol (PAP) -- -- prtChannelInformation entry: Bergman, et al. Standards Track [Page 31] RFC 3805 Printer MIB v2 June 2004 -- -- Printer Name -- Keyword: Name -- Syntax: Name -- Status: Optional -- Multiplicity: Single -- Description: The name of the printer -- within the AppleTalk naming scope chLPDServer(8), -- prtChannelInformation entry: -- -- Printer queue name -- Keyword: Queue -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: queue name as -- defined in [RFC1179]. chNetwareRPrinter(9), -- Novell, Inc. -- For each entry of this type, the -- prtChannelInformation must have a pair of -- keywords. For Netware 3.x channels this must -- be a (PServer, Printer) pair. For Netware -- 4.x channels and for IntranetWare channels -- this must be a (NDSTree, NDSPrinter) pair. -- -- prtChannelInformation entries: -- Print Server Name -- Keyword: PServer -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The Pserver's SAP name -- -- Printer Number -- Keyword: Printer -- Syntax: Integer -- Status: Mandatory -- Multiplicity: Single -- Description: The printer number -- -- NDSTree -- Keyword: NDSTree -- Syntax: Name -- Multiplicity: Single -- Description: The tree's SAP name Bergman, et al. Standards Track [Page 32] RFC 3805 Printer MIB v2 June 2004 -- -- NDS Printer object -- Keyword: NDSPrinter -- Syntax: Text (Unicode) -- Status: Mandatory -- Multiplicity: Single -- Description: The fully qualified -- name of the Printer -- -- In the Netware 3.x environment, the -- client checks the Bindery object -- representing the named PServer. The -- client then checks for queues which -- are associated with the numbered -- printer. In the 4.x and IntraNetware -- environment, the client looks up the -- queues which are associated with the -- NDS Printer Object in the named Tree. -- Depending on client access rights to -- those queues, the client submits jobs -- to the appropriate queue. chNetwarePServer(10), -- Novell,Inc. -- For each entry of this type, the -- prtChannelInformation must have a pair -- of keywords. For Netware 3.x channels -- this must be a (Server, PServer) pair. -- For Netware 4.x and IntranetWare -- channels, this must be a -- (NDSTree, NDSPServer) pair. -- -- prtChannelInformation entries: -- -- Server Name -- Keyword: Server -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The SAP name of the -- server for which the PServer is defined. -- -- PServer -- Keyword: PServer -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The bindery name of -- the PServer Bergman, et al. Standards Track [Page 33] RFC 3805 Printer MIB v2 June 2004 -- -- NDS Tree -- Keyword: NDSTree -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The NDS Tree name -- -- PServer -- Keyword: NDSPServer -- Syntax: Text (Unicode) -- Status: Mandatory -- Multiplicity: Single -- Description: The fully qualified -- name of the PServer object in the tree. -- -- In the 3.x environment, the client -- checks the bindery object -- representing the named PServer on the -- named Server. In the 4.x and -- IntranetWare environment, -- the client checks the NDS object -- representing the named PServer in the -- named Tree. In either case, the -- client then checks for all queues -- associated with the Pserver object. -- Depending on client access rights -- to those queues, the client submits -- jobs to the appropriate queue. chPort9100(11), -- DEPRECATED -- (see chPortTCP - 37; chBidirPortTCP - 38) chAppSocket(12), -- A bi-directional, LPD-like, protocol using -- 9101 for control and 9100 for data. -- Adobe Systems, Inc. chFTP(13), -- [RFC959] chTFTP(14), -- [RFC1350] chDLCLLCPort(15), chIBM3270(16), -- IBM Coax chIBM5250(17), -- IBM Twinax chFax(18), chIEEE1394(19), chTransport1(20), -- TCP port 35, for reserved TCP port list see -- [RFC3232]. This RFC should also be -- referenced for other channel -- enumerations utilizing TCP port Bergman, et al. Standards Track [Page 34] RFC 3805 Printer MIB v2 June 2004 -- numbers 0 through 1024. chCPAP(21), -- TCP port 170 -- Digital Equipment Corp. chDCERemoteProcCall(22), -- OSF -- DEPRECATED chONCRemoteProcCall(23), -- SUN Microsystems -- DEPRECATED chOLE(24), -- Microsoft -- DEPRECATED chNamedPipe(25), chPCPrint(26), -- Banyan chServerMessageBlock(27), -- File/Print sharing protocol used by -- various network operating systems -- from IBM 3Com, Microsoft and others -- -- prtChannelInformation entry: -- -- Service Name -- Keyword: Name -- Syntax: Name -- Status: Optional -- Multiplicity: Single -- Description: The service name of -- the printer chDPMF(28), -- IBM Infoprint chDLLAPI(29), -- Microsoft -- DEPRECATED chVxDAPI(30), -- Microsoft -- DEPRECATED chSystemObjectManager(31), -- IBM chDECLAT(32), -- Digital Equipment Corp. -- -- prtChannelInformation entries: -- -- Port Name -- Keyword: Port -- Syntax: Name -- Status: Conditionally -- Mandatory -- (see note below) -- Multiplicity: Single -- Description: LAT port name -- -- Service Name -- Keyword: Service -- Syntax: Name Bergman, et al. Standards Track [Page 35] RFC 3805 Printer MIB v2 June 2004 -- Status: Conditionally -- Mandatory -- Multiplicity: Single -- Description: LAT service name -- -- The LAT channel may be -- identified by either a port or -- service, so either a -- Port or Service entry must be -- specified, but not both. chNPAP(33), chUSB(34), -- Not in RFC 1759 -- Universal Serial Bus chIRDA(35), -- Not in RFC 1759 -- Infrared Data Assoc. Prot. chPrintXChange(36), -- Not in RFC 1759 -- PrintXChange Protocol chPortTCP(37), -- Not in RFC 1759 -- A unidirectional "raw" TCP -- channel that uses an administratively -- assigned TCP port address. -- -- prtChannelInformation entry: -- -- Port Number -- Keyword: Port -- Syntax: decimal number -- Status: Mandatory -- Multiplicity: Single -- Description: TCP port number chBidirPortTCP(38), -- Not in RFC 1759 -- A bi-directional version of chPortTCP -- -- prtChannelInformation entries: -- (See chPortTCP) chUNPP(39), -- Not in RFC 1759 -- Universal Network Printing -- Protocol(UNPP). A bi-directional, -- multiport network printing -- application protocol available on -- multiple transport protocols. -- Underscore, Inc. -- Contact: info@underscore.com chAppleTalkADSP(40), -- Not in RFC 1759 -- AppleTalk Data Stream Protocol. -- ADSP is part of the AppleTalk -- suite of protocols. -- It is a symmetric, connection- Bergman, et al. Standards Track [Page 36] RFC 3805 Printer MIB v2 June 2004 -- oriented protocol that makes -- possible the establishment -- and maintenance of full-duplex -- streams of data bytes between -- two sockets in an AppleTalk -- internet. -- See [APPLEMAC]. chPortSPX(41), -- Not in RFC 1759 -- Sequenced Packet Exchange (SPX) -- socket. -- Novell, Inc. Similar to TCP, a -- bi-directional data pipe using -- Novell SPX as a transport. -- -- prtChannelInformation entries: -- -- Network Number -- Keyword: Net -- Syntax: HexString -- Status: Mandatory -- Multiplicity: Single -- Description: The network number -- -- Node Number -- Keyword: Node -- Syntax: HexString -- Status: Mandatory -- Multiplicity: Single -- Description: The node number -- -- Socket Number -- Keyword: Socket -- Syntax: HexString -- Status: Mandatory -- Multiplicity: Single -- Description: The SPX socket number -- -- There must be exactly one "Net" and -- one "Node" and one "Socket" entry. A -- HexString is a binary value -- represented as a string of -- ASCII characters using hexadecimal -- notation. chPortHTTP(42), -- Not in RFC 1759 -- Hypertext Transfer Protocol. See [RFC1945] -- and [RFC2616]. chNDPS(43), -- Not in RFC 1759 -- Novell, Inc. Bergman, et al. Standards Track [Page 37] RFC 3805 Printer MIB v2 June 2004 -- -- prtChannelInformation entry: -- -- Printer Agent Name -- Keyword: PA -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The NDPS Printer -- Agent Name chIPP(44), -- Not in RFC 1759 -- Internet Printing Protocol (IPP), -- (IPP/1.1 - see [RFC2910] and [RFC2911]) -- also applies to all future versions of IPP. -- -- IPP Printer URI -- Keyword: URI -- Syntax: URI (Unicode UTF-8 per -- [RFC2396]) -- Status: Mandatory -- Multiplicity: Single -- Default: not applicable -- Description: URI of this IPP Printer -- within Internet naming scope. Unicode -- UTF-8 [RFC3629] string with -- hexadecimal escapes for any non-ASCII -- characters (per [RFC2396]). -- Conformance: An IPP Printer shall list all -- IPP URI it supports (one per IPP Channel -- entry). If a URI contains the 'http:' -- scheme it must have an explicit port. -- See: [RFC3629], [RFC2396], [RFC2910], -- [RFC2911]. -- -- IPP Printer Client Authentication -- Keyword: Auth -- Syntax: Keyword -- Status: Optional -- Multiplicity: Single -- Default: 'none' -- Description: A client authentication -- mechanism supported for this IPP Printer -- URI: -- 'none' -- no client authentication mechanism -- 'requesting-user-name' -- authenticated user in 'requesting- -- user-name' Bergman, et al. Standards Track [Page 38] RFC 3805 Printer MIB v2 June 2004 -- 'basic' -- authenticated user via HTTP Basic -- mechanism -- 'digest' -- authenticated user via HTTP Digest -- mechanism -- 'certificate' -- authenticated user via certificate -- mechanism -- Conformance: An IPP Printer should list -- all IPP client authentication mechanisms -- it supports (one per IPP Channel entry). -- See: [RFC2911] and [RFC2910]. -- -- IPP Printer Security -- Keyword: Security -- Syntax: Keyword -- Status: Optional -- Multiplicity: Single -- Default: 'none' -- Description: A security mechanism -- supported for this IPP Printer URI: -- 'none' -- no security mechanism -- 'ssl3' -- SSL3 secure communications channel -- protocol -- 'tls' -- TLS secure communications channel -- protocol -- Conformance: An IPP Printer should list -- all IPP security mechanisms it supports -- (one per IPP Channel entry). -- See: [RFC2246], [RFC2911]. -- -- IPP Printer Protocol Version -- Keyword: Version -- Syntax: Keyword -- Status: Optional -- Multiplicity: Multiple -- Default: '1.1' -- Description: All of the IPP protocol -- versions (major.minor) supported for -- this IPP Printer URI: -- '1.0' -- IPP/1.0 conforming Printer -- '1.1' -- IPP/1.1 conforming Printer Bergman, et al. Standards Track [Page 39] RFC 3805 Printer MIB v2 June 2004 -- Conformance: An IPP Printer should list -- all IPP versions it supports (all listed -- in each IPP Channel entry). An IPP -- Client should select the highest -- numbered version the IPP Client supports -- for use in all IPP Requests (for optimum -- interworking). -- See: [RFC2911]. chSMTP(45) -- Print Job submission via Simple Mail -- Transfer Protocol (SMTP) - see [RFC2821] -- -- prtChannelInformation entry: -- -- Keyword: Mailto -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Default: not applicable -- Description: The SMTP URL of the printer. } -- -- Interpreter Group TEXTUAL-CONVENTIONs -- PrtInterpreterLangFamilyTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtInterpreterLangFamily in RFC 1759. STATUS current DESCRIPTION "This enumeration indicates the type of interpreter that is receiving jobs." SYNTAX INTEGER { other(1), unknown(2), -- Not in RFC 1759 langPCL(3), -- PCL. Starting with PCL version 5, -- HP-GL/2 is included as part of the -- PCL language. -- PCL and HP-GL/2 are registered -- trademarks of Hewlett-Packard -- Company. langHPGL(4), -- Hewlett-Packard Graphics Language. -- HP-GL is a registered trademark of -- Hewlett-Packard Company. langPJL(5), -- Peripheral Job Language. Appears in -- the data stream between data intended -- for a page description language. -- Hewlett-Packard Co. Bergman, et al. Standards Track [Page 40] RFC 3805 Printer MIB v2 June 2004 langPS(6), -- PostScript (tm) Language -- Postscript - a trademark of Adobe -- Systems Incorporated which may be -- registered in certain jurisdictions langIPDS(7), -- Intelligent Printer Data Stream -- Bi-directional print data stream for -- documents consisting of data objects -- (text, image, graphics, bar codes), -- resources (fonts, overlays) and page, -- form and finishing instructions. -- Facilitates system level device -- control, document tracking and error -- recovery throughout the print -- process. -- IBM Corporation. langPPDS(8), -- IBM Personal Printer Data Stream. -- Originally called IBM ASCII, the name -- was changed to PPDS when the Laser -- Printer was introduced in 1989. -- Lexmark International, Inc. langEscapeP(9), -- Epson Corp. langEpson(10), langDDIF(11), -- Digital Document Interchange Format -- Digital Equipment Corp., Maynard MA langInterpress(12), -- Xerox Corp. langISO6429(13), -- ISO 6429. Control functions for -- Coded Character Sets (has ASCII -- control characters, plus additional -- controls for -- character imaging devices.) langLineData(14), -- line-data: Lines of data as -- separate ASCII or EBCDIC records -- and containing no control functions -- (no CR, LF, HT, FF, etc.) -- For use with traditional line -- printers. May use CR and/or LF to -- delimit lines, instead of records. -- See ISO 10175 Document Printing -- Application (DPA) [ISO10175]. langMODCA(15), -- Mixed Object Document Content -- Architecture -- Definitions that allow the -- composition, interchange, and -- presentation of final form -- documents as a collection of data -- objects (text, image, graphics, bar -- codes), resources (fonts, overlays) Bergman, et al. Standards Track [Page 41] RFC 3805 Printer MIB v2 June 2004 -- and page, form and finishing -- instructions. -- IBM Corporation. langREGIS(16), -- Remote Graphics Instruction Set, -- Digital Equipment Corp., Maynard MA langSCS(17), -- SNA Character String -- Bi-directional print data stream for -- SNA LU-1 mode of communication. -- IBM langSPDL(18), -- ISO 10180 Standard Page Description -- Language -- ISO Standard langTEK4014(19), -- Tektronix Corp. langPDS(20), langIGP(21), -- Printronix Corp. langCodeV(22), -- Magnum Code-V, Image and printer -- control language used to control -- impact/dot-matrix printers. -- QMS, Inc., Mobile AL langDSCDSE(23), -- DSC-DSE: Data Stream Compatible and -- Emulation Bi-directional print data -- stream for non-SNA (DSC) and SNA LU-3 -- 3270 controller (DSE) communications -- IBM langWPS(24), -- Windows Printing System, Resource -- based command/data stream used by -- Microsoft At Work Peripherals. -- Developed by the Microsoft -- Corporation. langLN03(25), -- Early DEC-PPL3, Digital Equipment -- Corp. langCCITT(26), langQUIC(27), -- QUIC (Quality Information Code), Page -- Description Language for laser -- printers. Included graphics, printer -- control capability and emulation of -- other well-known printer. -- QMS, Inc. langCPAP(28), -- Common Printer Access Protocol -- Digital Equipment Corp. langDecPPL(29), -- Digital ANSI-Compliant Printing -- Protocol -- (DEC-PPL) -- Digital Equipment Corp. langSimpleText(30), -- simple-text: character coded data, -- including NUL, CR , LF, HT, and FF -- control characters. See ISO 10175 Bergman, et al. Standards Track [Page 42] RFC 3805 Printer MIB v2 June 2004 -- Document Printing Application (DPA) -- [ISO10175]. langNPAP(31), -- Network Printer Alliance Protocol -- (NPAP). This protocol has been -- superseded by the IEEE 1284.1 TIPSI -- Std (ref. LangTIPSI(49)). langDOC(32), -- Document Option Commands, Appears in -- the data stream between data -- intended for a page description. -- QMS, Inc. langimPress(33), -- imPRESS, Page description language -- originally developed for the -- ImageServer product line. A binary -- language providing representations -- of text, simple graphics, and some -- large forms (simple -- bit-map and CCITT group 3/4 -- encoded).The -- language was intended to be sent over -- an 8-bit channel and supported early -- document preparation languages (e.g., -- TeX and TROFF). -- QMS, Inc. langPinwriter(34), -- 24 wire dot matrix printer for -- USA, Europe, and Asia except -- Japan. -- More widely used in Germany, and -- some Asian countries than in US. -- NEC langNPDL(35), -- Page printer for Japanese market. -- NEC langNEC201PL(36), -- Serial printer language used in -- the Japanese market. -- NEC langAutomatic(37), -- Automatic PDL sensing. Automatic -- sensing of the interpreter -- language family by the printer -- examining the document content. -- Which actual interpreter language -- families are sensed depends on -- the printer implementation. langPages(38), -- Page printer Advanced Graphic -- Escape Set -- IBM Japan langLIPS(39), -- LBP Image Processing System langTIFF(40), -- Tagged Image File Format (Aldus) Bergman, et al. Standards Track [Page 43] RFC 3805 Printer MIB v2 June 2004 langDiagnostic(41), -- A hex dump of the input to the -- interpreter langPSPrinter(42), -- The PostScript Language used for -- control (with any PDLs) -- Adobe Systems Incorporated langCaPSL(43), -- Canon Print Systems Language langEXCL(44), -- Extended Command Language -- Talaris Systems Inc. langLCDS(45), -- Line Conditioned Data Stream -- Xerox Corporation langXES(46), -- Xerox Escape Sequences -- Xerox Corporation langPCLXL(47), -- Not in RFC 1759 -- Printer Control Language. Extended -- language features for printing, and -- printer control. -- Hewlett-Packard Co. langART(48), -- Not in RFC 1759 -- Advanced Rendering Tools (ART). -- Page Description language -- originally developed for the Laser -- Press printers. -- Technical reference manual: "ART IV -- Reference Manual", No F33M. -- Fuji Xerox Co., Ltd. langTIPSI(49), -- Not in RFC 1759 -- Transport Independent Printer -- System Interface (ref. IEEE Std. -- 1284.1) langPrescribe(50), -- Not in RFC 1759 -- Page description and printer -- control language. It can be -- described with ordinary ASCII -- Technical reference manual: -- "PRESCRIBE II Programming Manual" langLinePrinter(51), -- Not in RFC 1759 -- A simple-text character stream which -- supports the control codes LF, VT, -- FF, and plus Centronics or -- Dataproducts Vertical Format Unit -- (VFU) language is commonly used on -- many older model line and matrix -- printers. langIDP(52), -- Not in RFC 1759 -- Imaging Device Protocol -- Apple Computer. Bergman, et al. Standards Track [Page 44] RFC 3805 Printer MIB v2 June 2004 langXJCL(53), -- Not in RFC 1759 -- Xerox Job Control Language (JCL). -- A Job Control language originally -- developed for the LaserPress printers -- and is capable of switching PDLs. -- Technical reference manual: -- "ART IV Reference Manual", No F33M. -- Fuji Xerox Co., Ltd. langPDF(54), -- Not in RFC 1759 -- Adobe Portable Document Format -- Adobe Systems, Inc. langRPDL(55), -- Not in RFC 1759 -- Ricoh Page Description Language for -- printers. -- Technical manual "RPDL command -- reference" No.307029 -- RICOH, Co. LTD langIntermecIPL(56), -- Not in RFC 1759 -- Intermec Printer Language for label -- printers. -- Technical Manual: "IPL Programmers -- Reference Manual" -- Intermec Corporation langUBIFingerprint(57), -- Not in RFC 1759 -- An intelligent basic-like programming -- language for label printers. -- Reference Manual: "UBI Fingerprint -- 7.1", No. 1-960434-00 -- United Barcode Industries langUBIDirectProtocol(58), -- Not in RFC 1759 -- An intelligent control language for -- label printers. -- Programmers guide: " UBI Direct -- Protocol", No. 1-960419-00 -- United Barcode Industries langFujitsu(59), -- Not in RFC 1759 -- Fujitsu Printer Language -- Reference Manual: -- "FM Printer Sequence" No. 80HP-0770 -- FUJITSU LIMITED langCGM(60), -- Not in RFC 1759 -- Computer Graphics Metafile -- MIME type 'image/cgm' langJPEG(61), -- Not in RFC 1759 -- Joint Photographic Experts Group -- MIME type 'image/jpeg' langCALS1(62), -- Not in RFC 1759 -- US DOD CALS1 (see MIL-STD-1840) Bergman, et al. Standards Track [Page 45] RFC 3805 Printer MIB v2 June 2004 -- MIME type 'application/cals-1840' langCALS2(63), -- Not in RFC 1759 -- US DOD CALS2 (see MIL-STD-1840) -- MIME type 'application/cals-1840' langNIRS(64), -- Not in RFC 1759 -- US DOD NIRS (see MIL-STD-1840) -- MIME type 'application/cals-1840' langC4(65) -- Not in RFC 1759 -- US DOD C4 (see MIL-STD-1840) -- MIME type 'application/cals-1840' } -- -- Input/Output Group TEXTUAL-CONVENTIONs -- PrtInputTypeTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtInputType in RFC 1759. STATUS current DESCRIPTION "The type of technology (discriminated primarily according to feeder mechanism type) employed by a specific component or components." SYNTAX INTEGER { other(1), unknown(2), sheetFeedAutoRemovableTray(3), sheetFeedAutoNonRemovableTray(4), sheetFeedManual(5), continuousRoll(6), continuousFanFold(7) } PrtOutputTypeTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtOutputType in RFC 1759. STATUS current DESCRIPTION "The Type of technology supported by this output subunit." SYNTAX INTEGER { other(1), unknown(2), removableBin(3), unRemovableBin(4), continuousRollDevice(5), mailBox(6), continuousFanFold(7) } Bergman, et al. Standards Track [Page 46] RFC 3805 Printer MIB v2 June 2004 -- -- Marker Group TEXTUAL-CONVENTIONs -- PrtMarkerMarkTechTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerMarkTech in RFC 1759. STATUS current DESCRIPTION "The type of marking technology used for this marking subunit." SYNTAX INTEGER { other(1), unknown(2), electrophotographicLED(3), electrophotographicLaser(4), electrophotographicOther(5), impactMovingHeadDotMatrix9pin(6), impactMovingHeadDotMatrix24pin(7), impactMovingHeadDotMatrixOther(8), impactMovingHeadFullyFormed(9), impactBand(10), impactOther(11), inkjetAqueous(12), inkjetSolid(13), inkjetOther(14), pen(15), thermalTransfer(16), thermalSensitive(17), thermalDiffusion(18), thermalOther(19), electroerosion(20), electrostatic(21), photographicMicrofiche(22), photographicImagesetter(23), photographicOther(24), ionDeposition(25), eBeam(26), typesetter(27) } PrtMarkerSuppliesTypeTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerSuppliesType in RFC 1759. STATUS current DESCRIPTION "The type of this supply." SYNTAX INTEGER { other(1), unknown(2), Bergman, et al. Standards Track [Page 47] RFC 3805 Printer MIB v2 June 2004 -- Values for Printer MIB toner(3), wasteToner(4), ink(5), inkCartridge(6), inkRibbon(7), wasteInk(8), opc(9), -- photo conductor developer(10), fuserOil(11), solidWax(12), ribbonWax(13), wasteWax(14), fuser(15), -- Not in RFC 1759 coronaWire(16), -- Not in RFC 1759 fuserOilWick(17), -- Not in RFC 1759 cleanerUnit(18), -- Not in RFC 1759 fuserCleaningPad(19), -- Not in RFC 1759 transferUnit(20), -- Not in RFC 1759 tonerCartridge(21), -- Not in RFC 1759 fuserOiler(22), -- Not in RFC 1759 -- End of values for Printer MIB -- Values for Finisher MIB water(23), -- Not in RFC 1759 wasteWater(24), -- Not in RFC 1759 glueWaterAdditive(25),-- Not in RFC 1759 wastePaper(26), -- Not in RFC 1759 bindingSupply(27), -- Not in RFC 1759 bandingSupply(28), -- Not in RFC 1759 stitchingWire(29), -- Not in RFC 1759 shrinkWrap(30), -- Not in RFC 1759 paperWrap(31), -- Not in RFC 1759 staples(32), -- Not in RFC 1759 inserts(33), -- Not in RFC 1759 covers(34) -- Not in RFC 1759 -- End of values for Finisher MIB } -- -- Media Path TEXTUAL-CONVENTIONs -- PrtMediaPathTypeTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMediaPathType in RFC 1759. STATUS current DESCRIPTION "The type of the media path for this media path." SYNTAX INTEGER { Bergman, et al. Standards Track [Page 48] RFC 3805 Printer MIB v2 June 2004 other(1), unknown(2), longEdgeBindingDuplex(3), shortEdgeBindingDuplex(4), simplex(5) } -- -- Console Group TEXTUAL-CONVENTIONs -- PrtConsoleColorTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtConsoleColor in RFC 1759. STATUS current DESCRIPTION "The color of this light." SYNTAX INTEGER { other(1), unknown(2), white(3), red(4), green(5), blue(6), cyan(7), magenta(8), yellow(9), orange(10) -- Not in RFC 1759 } PrtConsoleDisableTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtConsoleDisable in RFC 1759. STATUS current DESCRIPTION "This value indicates whether or not input is accepted from the operator console. A value of 'enabled' indicates that input is accepted from the console, and a value of 'disabled' indicates that input is not accepted from the console. " SYNTAX INTEGER { enabled(3), disabled(4) } -- -- Alert Group TEXTUAL-CONVENTIONs -- PrtAlertTrainingLevelTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtAlertTrainingLevel in RFC 1759. Bergman, et al. Standards Track [Page 49] RFC 3805 Printer MIB v2 June 2004 STATUS current DESCRIPTION "The level of training required to handle this alert, if human intervention is required. The noInterventionRequired value should be used if the event does not require any human intervention. The training level is an enumeration that is determined and assigned by the printer manufacturer based on the information or training required to handle this alert. The printer will break alerts into these different training levels. It is the responsibility of a management application in the system to determine how a particular alert is handled and how and to whom that alert is routed. The following are the four training levels of alerts: Field Service - Alerts that typically require advanced training and technical knowledge of the printer and its subunits. An example of a technical person would be a manufacturer's Field Service representative, or other person formally trained by the manufacturer or similar representative. Trained - Alerts that require an intermediate or moderate knowledge of the printer and its subunits. A typical example of such an alert is replacing a toner cartridge. Untrained - Alerts that can be fixed without prior training either because the action to correct the alert is obvious or the printer can help the untrained person fix the problem. A typical example of such an alert is reloading paper trays or emptying output bins on a low end printer. Management - Alerts that have to do with overall operation of and configuration of the printer. Examples of such management events are configuration change of subunits." SYNTAX INTEGER { other(1), unknown(2), untrained(3), trained(4), fieldService(5), management(6), noInterventionRequired(7) -- Not in RFC 1759 } PrtAlertGroupTC ::= TEXTUAL-CONVENTION -- Values in the range 1 to 29 must not be IANA-assigned without -- re-publishing Printer MIB. -- Values of 30 and greater are for use in MIBs that augment -- the Printer MIB, such as the Finisher MIB. -- This TC extracted from prtAlertGroup in RFC 1759. Bergman, et al. Standards Track [Page 50] RFC 3805 Printer MIB v2 June 2004 STATUS current DESCRIPTION "The type of subunit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of subunits. Wherever possible, the enumerations match the sub-identifier that identifies the relevant table in the Printer MIB. NOTE: Alert type codes have been added for the Host Resources MIB storage table and device table. These additional types are for situations in which the printer's storage and device objects must generate alerts (and possibly traps for critical alerts)." SYNTAX INTEGER { other(1), -- (2) is reserved for conformance information -- Values for Host Resources MIB hostResourcesMIBStorageTable(3), hostResourcesMIBDeviceTable(4), -- Values for Printer MIB generalPrinter(5), cover(6), localization(7), input(8), output(9), marker(10), markerSupplies(11), markerColorant(12), mediaPath(13), channel(14), interpreter(15), consoleDisplayBuffer(16), consoleLights(17), alert(18), -- Not in RFC 1759 -- Values (5) to (29) reserved for Printer MIB -- Values for Finisher MIB finDevice(30), -- Not in RFC 1759 finSupply(31), -- Not in RFC 1759 finSupplyMediaInput(32), -- Not in RFC 1759 finAttribute(33) -- Not in RFC 1759 -- Values (30) to (39) reserved for Finisher MIB } PrtAlertCodeTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtAlertCode in RFC 1759. STATUS current DESCRIPTION "The code that describes the type of alert for this entry in Bergman, et al. Standards Track [Page 51] RFC 3805 Printer MIB v2 June 2004 the table. Binary change event alerts describe states of the subunit while unary change event alerts describe a single event. The same alert code can be used for a binary change event or a unary change event, depending on implementation. Also, the same alert code can be used to indicate a critical or non-critical (warning) alert, depending on implementation. The value of prtAlertSeverityLevel specifies binary vs. unary and critical vs. non-critical for each event for the implementation. While there are some specific codes for many subunits, the generic codes should be used for most subunit alerts. The network management station can then query the subunit specified by prtAlertGroup to determine further subunit status and other subunit information. An agent shall not add two entries to the alert table for the same event, one containing a generic event code and the other containing a specific event code; the agent shall add only one entry in the alert table for each event; either generic (preferred) or specific, not both. Implementation of the unary change event alertRemovalOfBinaryChangeEntry(1801) is optional. When implemented, this alert code shall indicate to network management stations that the trailing edge of a binary change event has occurred and the corresponding alert entry has been removed from the alert table. As with all events, the alertRemovalOfBinaryChangeEntry(1801) alert shall be placed at the end of the alert table. Such an alert table entry shall specify the following information: prtAlertSeverityLevel warningUnaryChangeEvent(4) prtAlertTrainingLevel noInterventionRequired(7) prtAlertGroup alert(18) prtAlertGroupIndex the index of the row in the alert table of the binary change event that this event has removed. prtAlertLocation unknown (-2) prtAlertCode alertRemovalOfBinaryChangeEntry(1801) prtAlertDescription prtAlertTime the value of sysUpTime at the time of the removal of the binary change event from the alert table. Optionally, the agent may generate a trap coincident with Bergman, et al. Standards Track [Page 52] RFC 3805 Printer MIB v2 June 2004 removing the binary change event and placing the unary change event alertRemovalOfBinaryChangeEntry(1801) in the alert table. For such a trap, the prtAlertIndex sent with the above trap parameters shall be the index of the alertRemovalOfBinaryChangeEvent row that was added to the prtAlertTable; not the index of the row that was removed from the prtAlertTable." SYNTAX INTEGER { other(1), -- an event that is not represented -- by one of the alert codes -- specified below. unknown(2), -- The following generic codes are common to -- multiple groups. The NMS may examine the -- prtAlertGroup object to determine what group -- to query for further information. coverOpen(3), coverClosed(4), interlockOpen(5), interlockClosed(6), configurationChange(7), jam(8), subunitMissing(9), -- Not in RFC 1759 -- The subunit tray, bin, etc. -- has been removed. subunitLifeAlmostOver(10), -- Not in RFC 1759 subunitLifeOver(11), -- Not in RFC 1759 subunitAlmostEmpty(12), -- Not in RFC 1759 subunitEmpty(13), -- Not in RFC 1759 subunitAlmostFull(14), -- Not in RFC 1759 subunitFull(15), -- Not in RFC 1759 subunitNearLimit(16), -- Not in RFC 1759 subunitAtLimit(17), -- Not in RFC 1759 subunitOpened(18), -- Not in RFC 1759 subunitClosed(19), -- Not in RFC 1759 subunitTurnedOn(20), -- Not in RFC 1759 subunitTurnedOff(21), -- Not in RFC 1759 subunitOffline(22), -- Not in RFC 1759 subunitPowerSaver(23), -- Not in RFC 1759 subunitWarmingUp(24), -- Not in RFC 1759 subunitAdded(25), -- Not in RFC 1759 subunitRemoved(26), -- Not in RFC 1759 subunitResourceAdded(27), -- Not in RFC 1759 subunitResourceRemoved(28), -- Not in RFC 1759 subunitRecoverableFailure(29), -- Not in RFC 1759 subunitUnrecoverableFailure(30), Bergman, et al. Standards Track [Page 53] RFC 3805 Printer MIB v2 June 2004 -- Not in RFC 1759 subunitRecoverableStorageError(31), -- Not in RFC 1759 subunitUnrecoverableStorageError(32), -- Not in RFC 1759 subunitMotorFailure(33), -- Not in RFC 1759 subunitMemoryExhausted(34), -- Not in RFC 1759 subunitUnderTemperature(35), -- Not in RFC 1759 subunitOverTemperature(36), -- Not in RFC 1759 subunitTimingFailure(37), -- Not in RFC 1759 subunitThermistorFailure(38), -- Not in RFC 1759 -- General Printer group doorOpen(501), -- DEPRECATED -- Use coverOpened(3) doorClosed(502), -- DEPRECATED -- Use coverClosed(4) powerUp(503), powerDown(504), printerNMSReset(505), -- Not in RFC 1759 -- The printer has been reset by some -- network management station(NMS) -- writing into 'prtGeneralReset'. printerManualReset(506), -- Not in RFC 1759 -- The printer has been reset manually. printerReadyToPrint(507), -- Not in RFC 1759 -- The printer is ready to print. (i.e., -- not warming up, not in power save -- state, not adjusting print quality, -- etc.). -- Input Group inputMediaTrayMissing(801), inputMediaSizeChange(802), inputMediaWeightChange(803), inputMediaTypeChange(804), inputMediaColorChange(805), inputMediaFormPartsChange(806), inputMediaSupplyLow(807), inputMediaSupplyEmpty(808), inputMediaChangeRequest(809), -- Not in RFC 1759 -- An interpreter has detected that a -- different medium is need in this input -- tray subunit. The prtAlertDescription may -- be used to convey a human readable -- description of the medium required to -- satisfy the request. inputManualInputRequest(810), -- Not in RFC 1759 Bergman, et al. Standards Track [Page 54] RFC 3805 Printer MIB v2 June 2004 -- An interpreter has detected that manual -- input is required in this subunit. The -- prtAlertDescription may be used to convey -- a human readable description of the medium -- required to satisfy the request. inputTrayPositionFailure(811), -- Not in RFC 1759 -- The input tray failed to position correctly. inputTrayElevationFailure(812), -- Not in RFC 1759 inputCannotFeedSizeSelected(813), -- Not in RFC 1759 -- Output Group outputMediaTrayMissing(901), outputMediaTrayAlmostFull(902), outputMediaTrayFull(903), outputMailboxSelectFailure(904), -- Not in RFC 1759 -- Marker group markerFuserUnderTemperature(1001), markerFuserOverTemperature(1002), markerFuser