Comments - Raj Subramanian eponDeviceObjectTemperatureEventIndicationState, eponDeviceObjectPowerVoltageEventIndicationState , eponDeviceObjectGlobalEvent0State…………………. eponDeviceObjectGlobalEvent7State The description says ‘ this event defines the state of the *respective* event of the OAM Alarm Indications as specified in the [802.3ah] clause 57. But I could not locate these attributes in the Draft2.0 version of the standard. Can you give me pointers as to where I should be looking into? Editor’s reply: The alarms are not defined at the 802.3ah draft. I will remove this reference. However I still think that as alarms and event for device in access system they are needed so I suggest to keep them. I will add a description. |