One Comment Not Addressed Request to provide normalization for Reporting Format when Recommended Values cannot be used Recommended Values: Timer Recommended Value ----- ----------------- SONET Failure Indication Delay <10milliseconds IGP Hello Timer 1 second IGP Dead-Interval 3 seconds LSA Generation Delay 0 LSA Flood Packet Pacing 0 LSA Retransmission Packet Pacing 0 SPF Delay 0 Recommended Values were not included in revision –00, but were added for –01 at a reviewers request only for guidance It was decided by authors to _not_ include this because these variables contribute to a device’s convergence benchmark If a timer value cannot be set lower, then that contributes to the devices convergence time |